What to Do When a Peristaltic Pump Head Doesn't Rotate

0
2K

What to Do When a Peristaltic Pump Head Doesn't Rotate

As a precision fluid transfer device, a peristaltic pump whose pump head doesn't rotate can seriously affect its performance. Below, we will discuss in detail the possible reasons and solutions for a peristaltic pump head not rotating.

I. Possible Reasons Why a Peristaltic Pump Head Doesn't Rotate

1. Power Issues: First, check if the power cord is properly connected, if the fuse has blown, and if the internal power connection wires in the chassis are loose. These issues can all prevent the pump head from working normally.

2. Motor Failure: The motor is the core component of the peristaltic pump. If the motor fails, such as the drive board indicator light not illuminating or poor connection of the motor and drive board wires, it will cause the pump head to not rotate.  

3. Damaged Pump Head Rotor: If the pump frequently stops or the flow rate decreases, it may be that the pump head rotor is worn or cracked. In this case, the rotor needs to be replaced promptly.

II. Solutions for a Peristaltic Pump Head Not Rotating/Starting

1. Check Power and Motor: First, ensure the power cord is properly connected, the fuse is not blown, and check if the connection wires between the motor and the drive board are in good condition. If there are any problems, repair or replace them in a timely manner.

2. Clear Tubing: If the tubing is blocked, it can also cause the pump head to not rotate. At this time, cleaning fluid should be used to clear the pipes to ensure smooth passage of the fluid.

3. Replace Accessories: If the pump head rotor is damaged, a new rotor needs to be replaced promptly. At the same time, regularly inspect and replace worn contour components and other accessories to ensure the normal operation of the peristaltic pump.

III. How to Turn Off the External Control Mode of a Peristaltic Pump

In some cases, if the peristaltic pump is always in external control mode, it may cause the pump head to not rotate. At this time, it is necessary to turn off the external control mode. The specific method is as follows:

1. Enter the setup interface of the peristaltic pump and find the "External Control Enable" option.

2. Select the "Disable" option to deactivate the external control function.

3. Save the settings and exit the interface. At this point, the peristaltic pump should be able to start normally and the pump head should rotate.

In summary, a non-rotating peristaltic pump head can be caused by various reasons, requiring careful inspection and troubleshooting. Additionally, understanding how to turn off the external control mode is an important step in resolving such problems.

 

Pesquisar
Categorias
Leia Mais
Jogos
Ultimate Guide to Diablo 2 Rune Words: Crafting Powerful Items with Runestones
Ultimate Guide to Diablo 2 Rune Words: Crafting Powerful Items with Runestones In the dark and...
Por Casey 2025-01-25 02:21:24 0 2K
Outro
Galvanized Steel Applications Expanding Beyond Construction and Automotive
Galvanized Steel Market Prospects: Promoting Innovation, Infrastructure, and Sustainability until...
Por bhosalesuva2002 2025-08-05 06:13:24 0 758
Jogos
Maximize Your Squad's Potential with FIFA Ultimate Team Coins: The Ultimate Guide to Acquiring FC 26 Coins and FC26 Coins for Your Ultimate Gaming Experience
Maximize Your Squad's Potential with FIFA Ultimate Team Coins Embarking on your journey in the...
Por Casey 2025-07-10 15:23:31 0 769
Jogos
Titre : "Achat de Crédit FIFA : Guide Complet pour Maximiser vos Credits FC 25 et FC 26
Achat de Crédit FIFA : Guide Complet pour Maximiser vos Credits FC 25 et FC 26 Dans...
Por Casey 2025-10-09 00:52:01 0 217
Outro
Sports Mouthguard Market to Experience Rapid Growth and Expansion by 2032
The global sports mouthguard market, valued at USD 3.71 billion in 2021, is poised for...
Por dipali.k 2025-05-16 11:02:06 0 1K