CWDM Add Drop Multiplexer suppliers

0
12كيلو بايت

CWDM Add Drop Multiplexer suppliers OADM module (short for optical add-drop multiplexer), is a passive optical device used in WDM network system for multiplexing and routing different channels of light into or out of an current existing backbone ring.Add and drop here refer to the capability of adding one or more new wavelength channels to an existing multi channel WDM signals, dropping one or more channels passing those signals to another network path,so as to achieve the optical cross-connection. Arkoptics manufacture CWDM OADM 2CH Add Drop multiplexer,east and west, mux and demux in one ABS module equipped in one 1U 19” chassis. Customer can selected any CWDM 2 channels from ITU 1270nm to 1610nm range.Our 1U 19” Chassis will have clear channel port print (East-West) and COM-E, COM-W indications for easy patching. Customer logo can be printed on the front patch panel as well.At the meanwhile,we have mounting bracket on the chassis which can flexible to expand or reduce the mounting depth in datacenter cabinets. Features • Selected ITU wavelength from 1270nm to 1610nm • Available for CWDM OADM 1ch, 2ch, 4ch or 8ch multiplexer version • East and West,Mux and Demux in bi-directions • Additional Express/UPG port available • One ABS module in 1U 19” chassis rackmount • Come with 900um,2.0mm or 3.0mm patches • Can terminated with LC,SC,FC,ST and other types of optical connectors • 1U 19” chassis have COM-E, COM-W,channel East-West indications for easy patching • Mounting brackets for easy installation • Customized logo printing on the front patch panel Technical Specification Item Unit Parameters Channel spacing 20 nm ITU grids Wavelength rangenm1260 to1620 Channel centers (ITU or ITU+1)nm1270/1290...1610 or 1271/1291...1611 Passbandnm≥+/-6.5 Passband rippledB≤0.3 1CH OADM Add/Drop insertion lossdB≤0.8 dB 2CH OADM Add/Drop insertion lossdB≤1.0dB 4CH OADM Add/Drop insertion lossdB≤1.6dB Upgrade insertion loss (1 channel)dB≤0.8 dB Upgrade insertion loss (2 channel)dB≤1.2dB Upgrade insertion loss (4 channel)dB≤2.2dB Drop isolation (adj channel)dB≥30 dB Drop isolation (non-adj channel)dB≥50 dB Express isolationdB≥25 dB Polarization dependent lossdB≤0.2 dB Polarization mode dispersionps≤0.2 ps DirectivitydB≥50 dB Return lossdB≥45 dB Optical power handlingmW≤500 Operating temperature range°C-5 to 70 °C Storage temperature range°C-40 to +85 °C Fiber type SMF-28e with 0.9mm tube Connector Type LC,SC,FC,ST…… Package dimensionmmABS:100*80*10;1U 19” ChassisCWDM Add Drop Multiplexer suppliers website:http://www.arkoptics.com/cwdm-multiplexer/cwdm-add-drop-multiplexer/

البحث
الأقسام
إقرأ المزيد
الألعاب
Guida Completa per Comprare Crediti FC25 Sicuri: Scopri Tutti i Segreti sui Crediti FIFA 25
Guida Completa per Comprare Crediti FC25 Sicuri: Scopri Tutti i Segreti sui Crediti FIFA 25...
بواسطة Casey 2025-02-22 11:29:20 0 2كيلو بايت
Crafts
Healthcare Uninterruptible Power Supply (UPS) System Market:
Healthcare Uninterruptible Power Supply (UPS) System Market: Trends and Growth The healthcare...
بواسطة balajikal 2024-11-28 08:46:01 0 3كيلو بايت
الرئيسية
Machine Vision Market Revenue, Statistics, Industry Growth and Demand Analysis Research Report by 2030
Illuminating the Machine Vision Market: Growth Drivers, Companies, and Industry Trends...
بواسطة DivakarMRFR 2024-02-13 05:56:43 0 8كيلو بايت
أخرى
Orthopedic Doctor Boynton | Expert Care at Bone & Joint
Life in Boynton Beach is meant to be enjoyed to the fullest. From morning walks along the...
بواسطة boneandjoint879 2025-11-03 04:59:59 0 566
أخرى
UK LED Lighting Industry Expansion Forecast: Strong Growth Through 2033
UK LED Lighting Market Overview ​Market Size in 2024: USD 2.9 Billion Market Forecast in 2033:...
بواسطة ashutoshseo 2025-09-22 06:47:40 0 825